Solid wall insulation
Contents |
[edit] Introduction
It is only relatively recently that the external walls of buildings have been insulated, and only since the 1920s or 30s that they have even included cavities between the inner and outer layers that could accept insulation. Before this, walls were largely uninsulated and solid. Buildings built in this way they tend to lose more heat from the inside to the outside and so can be cold, can suffer condensation and can be expensive to heat.
Typically the U-values (a measure thermal conductance) of walls are:
- Solid brick wall 1.7 W/m2K.
- Cavity wall with no insulation 1.5 W/m2K.
- Insulated wall 0.3 W/m2K.
Insulating walls reduces heat loss and so the cost of heating. It also tends to increase internal surface temperatures, so reducing the likelihood of condensation. Insulating cavity walls is a relatively straight-forward process that involves filling the cavity with insulation. Insulating solid walls is more complicated, and so more expensive, involving insulation of either the inner or outer face of the wall.
[edit] Internal insulation
External walls can be insulated by fixing insulation boards to their internal surface, or by building an internal stud-wall adjacent to their surface and then insulating the cavity between the stud wall and the external wall. Internal insulation is generally less expensive than external insulation, although it may still take more than 10 years to recover the cost in terms of reductions in energy bills (Ref. uswitch).
Installing internal insulation can be very disruptive, involving the replacement of skirting boards, door frames, electrical fittings, shelves, radiators, pipe work, coving and cornices. It also reduces the habitable space within the building. Metal or wooden stud wall constructions require the greatest depth and so result in the greatest loss of habitable space. For example, if the stud and insulation construction is 120 mm thick, in a 3 m x 3 m corner room this would result in a loss of habitable floor area of more than 7%. Insulation boards are thinner, but more difficult to attach fixtures and fittings to.
Internal insulation can conceal damp problems, and so these must be dealt with before the insulation is fitted. In addition, where there are any gaps in the insulation, condensation problems can occur (see Cold bridge). This means that particular attention must be given to the standard of workmanship, and care taken with joints and to insulate areas around windows and where internal walls meet external walls.
Some condensation issues can be mitigated by adding a vapour membrane to the inner surface of the insulation to prevent damp air reaching the cold external wall, however, care must then be taken with jointing panels (if the membrane is integral to the panel) and if holes are subsequently made in the membrane, these must be re-sealed.
[edit] External insulation
The external surfaces of walls can be insulated by fixing an insulating material to them and then finishing the insulation with render or with cladding materials.
External insulation is generally less disruptive than internal insulation and it does not reduce the habitable area. It can also improve durability, weatherproofing and acoustic insulation and can reduce condensation problems. However, it may need planning permission, and tends to be more expensive. The cost of external insulation may take more than twenty years to recover through savings in energy bills (Ref. uswitch).
As with internal insulation, external insulation may require repositioning of pipework and other fittings, as well as window sills and sometimes even roof overhangs. External passageways or driveways may be made narrower, and there is the possibility of elements of the building protruding beyond the boundaries of the site.
Care must be taken to insulate window recesses to prevent cold bridging, and as with internal insulation, any existing damp problems should be resolved prior to installation. Where there is a damp-proof layer, insulation should not begin until above that layer.
[edit] Hansford report
In November 2015, the chief construction adviser to the government Peter Hansford published his recommendations for restoring the credibility of solid wall insulation.
He claimed that numerous examples of inadequate installation and poor workmanship have led to solid wall insulation developing something of a poor reputation.
His recommendations for restoring the credibility of solid wall insulation include:
- More robust accreditation of assessors and qualified installers.
- Development of guidance for assessors, designers, supervisors and customers.
- Establishment of a retrofit co-ordinator.
You can read about the report here.
For further guidance, see: https://historicengland.org.uk/images-books/publications/eehb-insulating-solid-walls/
[edit] Related articles on Designing Buildings Wiki
- BRE and Willmott Dixon project to retrofit of a 1920s semi-detached house.
- BREEAM Insulation.
- Cavity wall insulation.
- Cold bridge.
- Defects in brickwork.
- Designing out unintended consequences when applying solid wall insulation FB 79.
- Floor insulation.
- IHBC responds to Energy Company Obligation ECO4 and PAS 2035.
- Insulation specification.
- Insulation.
- Reducing thermal bridging at junctions when designing and installing solid wall insulation FB 61.
- Roof insulation.
- Solid Wall Insulation: Unlocking demand and driving up standards.
- Types of insulation.
- Understanding the performance of solid walls.
- U-value.
- Wall insulation and moisture risk.
[edit] External references
- uswitch, wall insulation types.
Featured articles and news
A case study and a warning to would-be developers
Creating four dwellings for people to come home to... after half a century of doing this job, why, oh why, is it so difficult?
Reform of the fire engineering profession
Fire Engineers Advisory Panel: Authoritative Statement, reactions and next steps.
Restoration and renewal of the Palace of Westminster
A complex project of cultural significance from full decant to EMI, opportunities and a potential a way forward.
Apprenticeships and the responsibility we share
Perspectives from the CIOB President as National Apprentice Week comes to a close.
The first line of defence against rain, wind and snow.
Building Safety recap January, 2026
What we missed at the end of last year, and at the start of this...
National Apprenticeship Week 2026, 9-15 Feb
Shining a light on the positive impacts for businesses, their apprentices and the wider economy alike.
Applications and benefits of acoustic flooring
From commercial to retail.
From solid to sprung and ribbed to raised.
Strengthening industry collaboration in Hong Kong
Hong Kong Institute of Construction and The Chartered Institute of Building sign Memorandum of Understanding.
A detailed description from the experts at Cornish Lime.
IHBC planning for growth with corporate plan development
Grow with the Institute by volunteering and CP25 consultation.
Connecting ambition and action for designers and specifiers.
Electrical skills gap deepens as apprenticeship starts fall despite surging demand says ECA.
Built environment bodies deepen joint action on EDI
B.E.Inclusive initiative agree next phase of joint equity, diversity and inclusion (EDI) action plan.
Recognising culture as key to sustainable economic growth
Creative UK Provocation paper: Culture as Growth Infrastructure.
Futurebuild and UK Construction Week London Unite
Creating the UK’s Built Environment Super Event and over 25 other key partnerships.
Welsh and Scottish 2026 elections
Manifestos for the built environment for upcoming same May day elections.
Advancing BIM education with a competency framework
“We don’t need people who can just draw in 3D. We need people who can think in data.”